Please read and save these instructions. Read carefully before attempting to assemble, install, operate or maintain the product described.
Protect yourself and others by observing all safety information. Failure to comply with instructions could result in personal injury and/or
property damage! Retain instructions for future reference.
Operating Instructions and Replacement Parts List GPH550PRO
The Aqua Pro pumps are general use
centrifugal water pumps.
This manual contains information that is
very important to know and understand.
This information is provided for SAFETY
and to PREVENT EQUIPMENT PROBLEMS.
To help recognize this information,
observe the following symbols.
Danger indicates
an imminently
hazardous situation which, if not avoided,
will result in death or serious injury.
Warning indicates
a potentially
hazardous situation which, if not avoided,
could result in death or serious injury.
Caution indicates a
potentially
hazardous situation which, if not avoided,
may result in minor or moderate injury.
Notice indicates
important
information, that if not followed, may
cause damage to equipment.
1. Know the pump application,
limitations, and potential hazards.
Read these rules and the instructions
carefully. Failure to follow them could
cause serious bodily injury and/or
property damage.
Never run engine in an
enclosed area. Exhaust gases
contain deadly poisonous carbon
monoxide, which has no odor or taste.
!
DANGER
NOTICE
!
CAUTION
!
WARNING
!
DANGER
322600-013 03/06
Do not use to pump flammable
or explosive fluids such as
gasoline, fuel oil, kerosene, etc. Do not
use in flammable and/or explosive
atmospheres. Pump should only be used
with liquids compatible with pump
component materials. Failure to follow
this warning can result in personal injury
and/or property damage.
2. Observe all safety precautions for the
handling of the fuel.
Do not refuel a hot engine.
Fuel spilled on a hot engine
could result in a fire or explosion. Do not
refuel a running engine.
3. Pump should be located and should
rest on a level solid foundation. Do
not suspend pump by means of the
discharge pipe.
Be sure pump is on
secure footing so it
doesn’t fall over.
4. Do not use torches or apply excessive
heat, fire or flames to this pump as an
explosion may result.
5. Before working on the unit, insulate
the wire from the spark plug,
disconnect the spark plug wire and
mount it on the grounding clip.
Complete pump
and piping system
MUST be protected against below
freezing temperature. Failure to do so
could cause serious damage and voids
the warranty.
6. Do not run pump dry. Water is
required to lubricate the shaft
seal.
7. Pumping chemicals or corrosive
liquids with this pump may shorten
NOTICE
NOTICE
!
WARNING
!
WARNING
the life of the pump and may be
hazardous to the operator.
8. Personal Safety:
a. Wear safety glasses at all times
when working with pumps.
b. Keep work area clean, uncluttered
and properly lighted; replace all
unused tools and equipment.
c. Keep visitors at a safe distance from
the work area.
d. Make workshop child-proof with
padlocks, master switches, and by
removing starter keys.
9. Always use a suction strainer with this
pump to filter large material.
This pump is designed to be self-
priming when installed and operated as
specified below.
1. The pump should be placed as close
as possible to the liquid being
pumped. A pump with 20 foot
suction lift will not remove water as
quickly as a pump with 5 foot
suction lift (Figure 1).
2. Suction hose and fitting must be
airtight.
Q
U
A
L
I
T
Y
A
S
S
U
R
A
N
C
E
P
R
O
G
R
A
M
Need
Assistance?
Call Us First!
1-877-278-2797
Description
Safety Guidelines
General Safety
Information
Installation
Figure 1
20 Ft.
Suction Lift
5 Ft.
Suction
Lift
Gas Powered
Water Pump
REMINDER: Keep your dated proof of purchase for warranty purposes! Attach it to this manual or file it for safekeeping.
Vue de la page 0
1 2 3 4 5 6 ... 11 12

Résumé du contenu

Page 1 - Water Pump

Please read and save these instructions. Read carefully before attempting to assemble, install, operate or maintain the product described.Protect your

Page 2 - (Continued)

4 SPMANGUERA EN LONA PARA DESCARGAREPUESTO #16511• Económica• Liviana• Resistente al aceite, químicos no muyagresivos, abrasión y luz solar • No le da

Page 3 - Semi-Trash Pump Performance

Por repuestos, llame al 1-877-278-27975 SPInstrucciones de Funcionamiento y Lista de Piezas de RepuestoArtículoRef. Descripción GPH550PRO Cant.1 Motor

Page 4

6 SPInstrucciones de Funcionamiento y Lista de Piezas de RepuestoGarantía LimitadaDurante un (1) año a partir de la fecha de compra, Aqua Pro (“Wayne

Page 5 - No. Description GPH550PRO Qty

Operating Instructions and Replacement Parts List2An air leak in thesuction line mayprevent priming of the pump. Use ofthread sealant is recommended.

Page 6 - Limited Warranty

3Operating Instructions and Replacement Parts ListFEET FRICTION LOSS IN 100 FEET OF PLASTIC PIPEGallons Per MinutePipeSize 20 25 30 40 50 60 80 100 12

Page 7 - Motor a Gasolina

4LAY FLAT DISCHARGE HOSEPART #16511 • Economical• Lightweight• Resistant to oils, light chemicals, abrasion and sunlight• Will not rot, mildew or abso

Page 8 - ADVERTENCIA

For Replacement Parts, call 1-877-278-27975Item PartNo. Description GPH550PRO Qty1 Honda Engine 57812-001 12 Shaft Seal Kit 66047-WYN1 13 Suction Flan

Page 9

6Operating Instructions and Replacement Parts ListLimited WarrantyFor one year from date of purchase, Aqua Pro (”Wayne Water Systems“) will repair or

Page 10

Bomba Hidráulica conMotor a GasolinaSírvase leer y guardar estas instrucciones. Lea atentamente antes de intentar ensamblar, instalar, hacer funcionar

Page 11 - Artículo

Una pérdida de aire en la línea desucción puede impedir el cebado dela bomba. Se recomienda el uso de unsellador de rosca.Las líneas de succión deben

Page 12 - Garantía Limitada

3 SPPÉRDIDA DE ALTURA POR FRICCIÓN EN 100 PIES (30 m) DE TUBERÍA DE PLÁSTICODiá. de la Galones por MinutoTubería 20 25 30 40 50 60 80 100 12011/45.6 8